– 15 –
11-2-4. Only Fan Does Not Work
<Precheck>
(1) Does fan rotate even in the cool mode and the fan only mode?
<Checking Procedures>
Points to which multimeter
probes are applied
Polarity
( + )
Q02"E"
(+ 12V)
Pin 2 of RY01
Pin 2 of RY02
Pin 2 of RY03
When each
relay is ON
Polarity
( )
Condition
Normal voltage value
DC12V
Polarity
( )
See items "NO
power turns ON"
NO
NO
NO
NO
YES
YES
YES
YES
Turn power ON.
Does operation on control panel flash?
Check power supply for Fan motor
Do fan relays RY01,RY02 and RY03 change over?
Points to which multimeter
probes are applied (Connector CN03)
COM
(RED)
H RY01
(BLK)
M RY02
(ORN)
L RY03
(BLU)
When each
relay is ON
Condition
Normal voltage value
AC220/230/240V
NO
Check Fan motor winding resistance
Points to which multimeter
probes are applied .
BLACK
BLUE
BLACK
BLUE
RED
WHITE
ORANGE
ORANGE
49
47
32
32
Condition
Nolmal resistance
value (
W
)
Replace.
Replace MF
capacitor.
Replace Fan
motor.
Relay is faulty.
Note:
Check the relays with
the fan motor
Polarity
( + )
Disconnect
fan motor
lead wire
MF capacitor
is faulty.
Fan motor
is faulty.
Operations
Remedies
Check items
Major possible
causes
Item by
symptom
Содержание RAC-08EW-E