![Toshiba RAC-08EW-E Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/toshiba/rac-08ew-e/rac-08ew-e_service-manual_1135479020.webp)
– 20 –
(3) Window has been kept open while raining, and
after that, cooling operation is started.
•
On rainy days, relative humidity may become
as high as 90% or higher. If doors or windows
are open to the outside, close them.
(4) When a man goes in and out between a room
with high humidity and one with low humidity. Or,
in case there is no door between such rooms.
•
Even if there is no moisture generating source
in the room where the air conditioner is in-
stalled, in case people go in from and out to a
room with high humidity frequently, or in case
there is no door between the rooms, the situ-
ation becomes the same.
(B) Water Leaks
Causes:
(1) There is a moisture generating source in the room.
•
Note that, even if a ventilation fan is not in
operation, if it is open to the outside, the con-
dition is same as the one in operation.
(2) Air volume is remarkably reduced.
•
Air filter is blocked, resulting in the reduction
of air volume.
•
Low fan operation causes the lowering of run-
ning voltage, resulting in the reduction of air
volume.
•
If the voltage is in the range of 198 – 264V, it
is normal.
Installation condition of the air
conditioner is defective.
Normal
Dew condensation on the
external body.
Water stays here.