– 7 –
Conditions
Surface temp. of heat exchanger
interchanging pipe (°C)
T
1
10
17
5
Outdoor
35/24
43/26
21/15
Ambient temp.
conditions DB/WB (°C)
Indoor
27/19
32/23
21/15
T
2
50
57
34
Cooling
Standard
High temperature
Low temperature
7. REFRIGERATING CYCLE DIAGRAM
RAC-08EW-E
Fig. 7-1
RAC-08EW-E
Table 7-1
Note:
Measure the heat exchanger temperature at the center of U-bend. (By means of thermistor thermometer.)
Capillary tube
I.D : 1.2 mm
O.D : 2.04 mm
Length : 400 mm
Evaporator
T1
Suction tube
I.D : 6.8 mm
O.D : 8.0 mm
Comp-
ressor
Sub condenser (air)
Delivery tube
I.D : 4.8 mm
O.D : 6.0 mm
Main condenser (Water)
T2