(2)Display of Outdoor Unit Information (Displayed on Each Outdoor Unit)
l
i
a
t
e
d
y
a
l
p
s
i
D
3
0
W
S
2
0
W
S
1
0
W
S
1
1
1
]
4
U
[
o
t
]
1
U
[
:
.
o
N
t
i
n
u
r
o
o
d
t
u
O
A
a
t
a
d
r
o
r
r
E
B Check code (only latest one displayed)
If there is no check code, [– – –] is displayed.
If there is sub-code, check code [
] and sub-code [–
] are displayed
alternately, for 3 seconds and 1 second, respectively.
<SW04> push SW function: Fan operation at outdoor unit with error. 7-segment display section A: [E.1]
<SW04 + SW05> push SW function: Fan operation at outdoor unit without error. 7-segment display section A: [E.0]
<SW05> push SW function: Fan operation function check mode is cancelled.
2
–
A
–
B –
3
Operation mode
A Stop [… …]
Normal cooling: [… C], Normal heating: [… H], Normal defrosting: [… J]
B –
4
Outdoor unit HP capacity
A 8HP: [… 8], 10HP: [… 10], 12HP: [… 12],
14HP: [14], 16HP: [16]
B […HP]
5
Compressor operation command
* Operation data of each compressor is displayed in turn in 2 second intervals.
If compressor No. 3 does not exist, [– –.– – –] is displayed.
Normal: Compressor speed (rps) is displayed in decimal format.
7-segment display (A/B): [C1.
]
[C2.
]
[C3.
]
...
<SW04> push SW function: Switches to display of operating current (decimal value).
7-segment display (A/B): [i1.
]
[i2.
]
[i3.
]
...
Pressing of <SW05> restores normal display.
6
Outdoor fan mode
A [FP]
B Mode 0 to 63: [… 0] to [63]
7
Compressor backup
A [C.b.]
B Displays compressor backup setting status
Normal: [… … …]
Compressor No. 1 backup: [1 … …]
Compressor No. 2 backup: [… 1 …]
Compressor No. 3 backup: [… … 1]
8
–
A
–
B –
9
Control valve output data
Displays control output status of solenoid valve
A
B
…
…
…
1
.
H
F
F
O
:
2
e
v
l
a
v
y
a
w
-
4
/
N
O
:
e
v
l
a
v
y
a
w
-
4
…
…
…
0
.
H
N
O
:
2
e
v
l
a
v
y
a
w
-
4
/
F
F
O
:
e
v
l
a
v
y
a
w
-
4
10
0
0
1
…
.
2
F
F
O
:
6
V
S
/
F
F
O
:
5
V
S
/
N
O
:
2
V
S
0
1
0
…
.
2
N
O
:
6
V
S
/
N
O
:
5
V
S
/
F
F
O
:
2
V
S
1
0
0
…
.
2
N
O
:
6
V
S
/
F
F
O
:
5
V
S
/
F
F
O
:
2
V
S
11
SV3A: ON / SV3B: OFF / SV3C: OFF / SV3D: OFF
3. 1
0 0 0
SV3A: OFF / SV3B: ON / SV3C: OFF / SV3D: OFF
3. 0
1 0 0
SV3A: OFF / SV3B: OFF / SV3C: ON / SV3D: OFF
3. 0
0 1 0
SV3A: OFF / SV3B: OFF / SV3C: OFF / SV3D: ON
3. 0
0 0 1
12
0
0
1
…
.
4
F
F
O
:
3
4
V
S
/
F
F
O
:
2
4
V
S
/
N
O
:
1
4
V
S
0
1
0
…
.
4
F
F
O
:
3
4
V
S
/
N
O
:
2
4
V
S
/
F
F
O
:
1
4
V
S
1
0
0
…
.
4
N
O
:
3
4
V
S
/
F
F
O
:
2
4
V
S
/
F
F
O
:
1
4
V
S
13
0
…
…
…
.
A
F
F
O
:
F
3
V
S
1
…
…
…
.
A
N
O
:
F
3
V
S
14
PMV1/PMV2 opening
Displays opening data in decimal format (total opening)
. P
…
t
a
m
r
o
f
l
a
m
i
c
e
d
n
i
a
t
a
d
g
n
i
n
e
p
o
s
y
a
l
p
s
i
D
g
n
i
n
e
p
o
4
V
M
P
5
1
. P
16
Oil level judgment status
]
.
L
o
[
A
l
a
m
r
o
N
B Initial display: [… … …], Oil level judgment result: [#. .$]
Displayed letters #, and $ represent judgment results for compressor Nos.
1, 2 and 3, respectively (“0” for normal and “1” or “2” for low level).
<SW04> push SW function: Displays low level confirmed judgment result of each compressor.
* Pressing of <SW05> restores
normal display.
A [L d.]
B Compressor No. 1 low level being confirmed: [L … …]
Compressor No. 2 low level being confirmed: [… L …]
Compressor No. 3 low level being confirmed: [… … L]
Содержание MMY-MAP0804HT7JP
Страница 23: ... 22 1 Wiring Diagrams 1 1 Outdoor Unit Models MMY MAP0804 MAP1004 and MAP1204 ...
Страница 24: ... 23 Models MMY MAP1404 and MAP1604 ...
Страница 35: ... 34 1 2 10 Slim Duct Type AP024 AP027 Models MMD AP0244SPH MMD AP0274SPH ...
Страница 38: ... 37 1 2 13 High Wall Type 3 series Models MMK AP0073H AP0093H AP0123H AP0153H AP0183H AP0243H ...
Страница 52: ... 51 2 5 Parts Layout in Outdoor Unit 8 10 12HP Model MMY MAP0804 MAP1004 MAP1204 ...
Страница 53: ... 52 14 16HP Model MMY MAP1404 MAP1604 ...
Страница 57: ... 56 2 7 2 Inverter P C board for compressor MCC 1596 A3 IPDU ...
Страница 323: ......