19
Operation procedure
1 2 3 4 5 6 7 8
End
8
4
6
5, 7
UNIT
SET
CL
UNIT No.
CODE No.
SET DATA
R.C. No.
1
3
2
UNIT
SET
CL
UNIT No.
CODE No.
SET DATA
R.C. No.
To finish the setup
Cancel of line selection
• To change all the indoor addresses from an arbitrary wired remote controller;
(When the setup operation with automatic address has finished, this change is available.)
Contents : Using an arbitrary wired remote controller, the indoor unit address can be changed for each same
refrigerant cycle line
∗∗∗∗∗
Change the address in the address check/change mode.
<Procedure> (Operation while air conditioner stops)
1
Push the timer time
+
buttons simultaneously for 4 seconds or more.
Firstly, the line 1, item code
AC
(Address Change) is displayed.
2
Using
UNIT
+
buttons, select the line address.
3
Push
SET
button.
• The indoor address, which is connected to the refrigerant line of the selected outdoor unit is displayed and the
fan is turned on.
First the current indoor address is displayed on the setup data. (Line address is not displayed.)
4
The indoor address of the setup data moves up/down by the timer time
/
buttons.
Change the setup data to a new address.
5
Push
SET
button to determine the setup data.
6
Every pushing
UNIT
button, the indoor unit numbers in the same refrigerant line are succes-
sively displayed. Only fan of the selected indoor unit operates.
Repeat the procedure
4
to
6
and change all the indoor addresses so that they are not duplicated.
7
Push
SET
button.
(All the displays on LCD go on.)
8
Push
button to finish the procedure.
Here, if the unit No. is not called up, the outdoor
unit in this line does not exist.
Push
CL
button, and then select a line
according to procedure
2
.
7
ADDRESS SETUP
Содержание MAP0601HT7