Connecting Hardware Devices
Cooling Fans
55
2
Unplug the two fan cables from the server board. The cable for fan #1 goes to
connector FAN2A, and the cable for fan #2 goes to FAN3A.
3
Press the tabs on both sides of the inoperative fan and lift it out of the fan assembly.
Replacing a System Fan
1
Insert the new fan into the fan assembly, making sure that the flow and rotation
arrows on the fan point correctly.
2
Plug the fan cables back into the connectors on the server board.
3
Reinstall the access cover, reconnect all signal and power cables, then turn on the
server. For instructions, read
Maintenance Overview
on page 50.