Getting Started
Installing the Server in a Rack
34
Installing the Server in a Rack
This section contains information and instructions on installing the server in a rack.
Choosing a Location
Choose an appropriate location for the server that is structurally and environmentally
suitable for the equipment.
Structural Considerations
Make sure the floor or supporting surface can support the weight of the rack when fully
loaded. In addition, make sure that the distance from the surface supporting the rack to
the ceiling is sufficient to allow air to flow freely. Ensure that there is enough space
around the rack to allow for server installation and maintenance.
Environmental Considerations
Install the rack on a level surface in a clean, dust-free, and well-ventilated environment.
The area should be free from:
❖
Direct sunlight
❖
Vibration
❖
Liquids and corrosive chemicals
❖
Equipment that generates a strong electromagnetic field, such as large motors or
speaker phones
❖
Rapid changes in temperature or humidity and sources of temperature change such
as air conditioner vents, fans, or heaters
❖
Extreme heat, cold, or humidity. Adhere to the following temperature and humidity
guidelines:
Temperature: 50 to 89 degrees F (10 to 32 degrees C)
Relative humidity: 40% to 80% (non-condensation)
If the ambient temperature is too high or too low, wait about an hour after the temperature
is within operational range before using the server.
CAUTION: To prevent damage to equipment, keep the rack and server free from
condensation during use and storage.