JKSSS+ Series - 79
JKSSS+ Series
2.3 - 4.2KV
MP.7 Statistics (Metering Page 7)
Displays the statistical trip information.
Screen 1:
Displays the total of megawatt hours.
Screen 2:
Displays the accumulated total running hours.
Screen 3:
Clears the total running hour count.
Screen 4:
D
isplays the total number of trips since the
last clearing the statistical data and the total
number of short circuit trips.
Screen 5:
Disp
lays the numbers of start overload and
run overload trips since the last clearing of the
statistical data.
Screen 6:
Di
splays the number of frequency trips and
Imbalance trips.
Screen 7:
Di
splays the number of overcurrent trips.
Screen 8:
Displays the number of Stator and non-Stator
RTD Trips.
Screen 9:
Displays the number of Ground Fault Hi and
Lo Set trips.
Screen 10:
Di
splays the number of acceleration time trips.
Screen 11:
Displ
ays the number of start under curve trips.
Screen 12:
D
isplays the number start over curve trips.
Screen 13:
Di
splays the number of I
2
T start curve trips.
Screen 14:
D
isplays the number of learned start curve
trips.
Screen 15:
Displa
ys the number of fail shunt trips.
Screen 16:
Dis
plays the number of phase loss trips.
Screen 17:
Dis
plays the number of tachometer
acceleration trips.
Screen 18:
D
isplays the number of undervoltage and
overvoltage trips.
Screen 19:
Di
splays the number of power factor trips.
Screen 20:
Disp
lays the number of phase reversal trips.
Screen 21:
Displays the number of external input #1 trips.
Screen 22:
Displays the number of external input #2 trips.
Screen 23:
Displays the number of external input #3 trips.
Screen 24:
Displays the number of external input #4 trips.
Screen 25:
Requires a Security Level 2 password to clear
the statistics.
RUNNING HOURS TOTAL
TIME: ## ## HOURS
TOTAL TRIPS: ###
S/C TRIPS: ###
START O/L TRIPS: ###
RUN O/L TRIPS: ###
I/B TRIPS: ###
OVERCURRENT
TRIPS: ###
STATOR TRIPS: ###
G/F HISET TRIPS: ###
G/F LOSET TRIPS: ###
ACCELERATION TIME
TRIPS: ###
START UNDER CURVE
TRIPS: ###
START OVER CURVE
TRIPS: ###
PRESS ENTER TO
CLEAR RUN HOURS
MENU
METERING PAGE 7
STATISTICS
Screen 5
Screen 6
Screen 7
Screen 8
Screen 9
Screen 10
Screen 11
Screen 12
Screen 13
Screen 14
Screen 15
Screen 16
Screen 17
Screen 18
Screen 22
Screen 23
Screen 24
Screen 25
Screen 4
MWH TOTAL
: ###
Screen 1
Screen 2
Screen 3
NON-STATOR TRIPS: ###
FREQUENCY TRIPS: ###
I*I*T START CURVE
TRIPS: ###
TRIPS: ###
FAIL SHUNT TRIP
TRIPS: ###
PHASE LOSS TRIP
TRIPS: ###
TACH ACCEL TRIP
TRIPS: ###
U/V TRIPS: ###
O/V TRIPS: ###
Screen 19
POWER FACTOR
TRIPS: ###
Screen 20
PHASE REVERSAL
TRIPS: ###
Screen 21
EXT INP #1: ###
EXT INP #2: ###
EXT INP #3: ###
EXT INP #4: ###
PRESS ENTER TO
CLEAR STATISTICS
LEVEL 2 Password required
LEARNED START CURVE
Содержание JKSSS Plus Series
Страница 2: ......
Страница 6: ...Reference Chart ...
Страница 45: ...JKSSS Series 39 JKSSS Series 2 3 4 2KV 5 1 5 Relay Configuration Setpoint Page 5 ...
Страница 90: ...JKSSS Series 84 JKSSS Series 2 3 4 2KV 7 3 Overload Curve Definition ...
Страница 92: ...JKSSS Series 86 JKSSS Series 2 3 4 2KV 7 5 Typical Wiring Diagram ...
Страница 93: ...JKSSS Series 87 JKSSS Series 2 3 4 2KV ...
Страница 95: ...JKSSS Series 89 JKSSS Series 2 3 4 2KV ...