TOSHIBA
I 19
TOSHIBA
I 19
Maximum heating capacity and power consumption
HWT-801H(R)W-E
Power (kW)
VLT (°C)
30
35
40
45
50
55
60
65
TO (°C)
-25
4.37
4.43
4.49
4.55
4.61
4.67
4.51
--
-20
5.40
5.45
5.50
5.27
5.54
5.54
5.31
--
-15
6.42
6.46
6.50
6.54
6.48
6.41
6.10
--
-10
7.60
7.49
7.47
7.45
7.23
7.00
6.67
--
-7
8.30
8.11
8.06
8.00
7.68
7.35
7.01
--
-2
9.35
9.24
9.20
9.15
8.97
8.79
7.78
--
2
10.50
10.30
10.28
10.26
9.88
9.50
8.40
--
7
12.39
11.90
11.83
11.75
10.86
9.96
9.07
5.08
10
13.02
12.57
12.46
12.36
11.56
10.76
9.96
5.09
12
13.44
13.01
12.89
12.77
12.03
11.29
10.55
5.09
15
13.69
13.22
13.04
12.87
12.11
11.36
10.60
5.08
20
14.10
13.57
13.30
13.03
12.25
11.47
10.69
5.06
Power
consumption (kW)
VLT (°C)
30
35
40
45
50
55
60
65
TO (°C)
-25
1.99
2.22
2.45
2.68
2.98
3.27
3.21
--
-20
2.14
2.41
2.68
2.83
3.15
3.36
3.41
--
-15
2.30
2.60
2.91
3.21
3.33
3.44
3.61
--
-10
2.55
2.78
3.04
3.31
3.43
3.54
3.67
--
-7
2.70
2.88
3.13
3.37
3.49
3.60
3.71
--
-2
2.48
2.71
2.99
3.26
3.46
3.65
3.61
--
2
2.57
2.77
3.08
3.38
3.47
3.56
3.53
--
7
2.41
2.62
3.01
3.39
3.43
3.47
3.51
2.19
10
2.42
2.63
3.00
3.38
3.42
3.47
3.52
2.06
12
2.42
2.63
3.00
3.37
3.42
3.47
3.52
1.98
15
2.42
2.63
3.01
3.39
3.42
3.46
3.49
1.90
20
2.42
2.62
3.02
3.42
3.43
3.44
3.45
1.76
Coefficient of perfor-
mance (COP)
VLT (°C)
30
35
40
45
50
55
60
65
TO (°C)
-25
2.20
2.00
1.83
1.70
1.55
1.43
1.40
--
-20
2.52
2.26
2.05
1.86
1.76
1.65
1.56
--
-15
2.80
2.48
2.24
2.04
1.95
1.86
1.69
--
-10
2.98
2.70
2.46
2.25
2.11
1.98
1.82
--
-7
3.07
2.82
2.58
2.37
2.20
2.04
1.89
--
-2
3.78
3.41
3.08
2.81
2.60
2.41
2.16
--
2
4.08
3.72
3.34
3.04
2.85
2.67
2.38
--
7
5.14
4.54
3.94
3.47
3.16
2.87
2.58
2.32
10
5.39
4.79
4.15
3.66
3.38
3.10
2.83
2.46
12
5.55
4.95
4.30
3.79
3.52
3.25
3.00
2.57
15
5.66
5.03
4.34
3.80
3.54
3.28
3.03
2.68
20
5.84
5.18
4.40
3.81
3.57
3.33
3.10
2.88
▪
Heating capacity and power consumption at maximum heating capacity
▪
Heating capacity and power consumption at maximum compressor speed
▪
Power consumption without water pump
▪
Heating capacity and power consumption are measured according to EN 14511
TO: Outdoor temperature (TK°C)
VLT: Supply water temperature (°C)
HWT
-801H(R)W-E NOMINAL HEA
TING CAP
ACITY
Содержание ESTIA R32 HWT-1101F21MT6W-E
Страница 1: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...
Страница 3: ...8 11 14 16 h LI 1 Ph LI 1 Ph LI h LI 1 Ph LI 1 Ph LI 3 Ph 1 Ph 3 Ph 3 Ph h h 1 Ph 3 Ph 3 Ph ...
Страница 8: ......
Страница 26: ...26 I TOSHIBA 26 I TOSHIBA SCHEMA 1 0 ...
Страница 27: ...TOSHIBA I 27 TOSHIBA I 27 SCHEMA 1 1 ...
Страница 28: ...28 I TOSHIBA 28 I TOSHIBA SCHEMA 2 0 ...
Страница 29: ...TOSHIBA I 29 TOSHIBA I 29 SCHEMA 2 1 ...
Страница 30: ...30 I TOSHIBA 30 I TOSHIBA SCHEMA 3 0 ...
Страница 31: ...TOSHIBA I 31 TOSHIBA I 31 SCHEMA 3 1 ...
Страница 32: ...32 I TOSHIBA 32 I TOSHIBA SCHEMA 4 0 ...
Страница 33: ...TOSHIBA I 33 TOSHIBA I 33 SCHEMA 4 1 ...
Страница 34: ...34 I TOSHIBA 34 I TOSHIBA SCHEMA 5 0 ...
Страница 35: ...TOSHIBA I 35 TOSHIBA I 35 SCHEMA 6 0 ...
Страница 36: ...36 I TOSHIBA 36 I TOSHIBA SCHEMA 7 0 ...
Страница 37: ...TOSHIBA I 37 TOSHIBA I 37 WIRING DIAGRAM 230 V ...
Страница 38: ...38 I TOSHIBA 38 I TOSHIBA WIRING DIAGRAM 400V ...
Страница 41: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...