8 I
TOSHIBA
8 I
TOSHIBA
Start and configuration
Select "DN for hydro unit" in the "Submenu settings" to change the DN codes of the hydro unit.
Define the following initial settings and the other set points:
Setting the DN codes of the hydro unit
Storage location
Function code
no .
*HB= Hydrobox EEPROM
*RC= Remote Control
FC description
HB*
RC*
Range
Preset
Additional info
System setup
(DPSW replacement)
Used to activate the external heating output
0 = E
xternal heating output deactivated
1 = External heating output activated
6B0
-
0~1
0
Only with a bivalent heating system
Integration of an external heating system
0 = Integrated downstream of 3-way valve
1 = Integrated upstream of 3-way valve
6B1
-
0~1
0
Only for a bivalent heating system (oil, gas, etc.)
Explained in the diagrams on the next page
If an external hot water thermostat is connected
0 = No external hot water thermostat connected
1 = External hot water thermostat connected
6B2
-
0~1
0
Use of an external hot water thermostat
(TTW sensor not required)
If an external room thermostat is used
0 = No external room thermostat
1 = External room thermostat connected
6B3
-
0~1
0
Only when using an external room thermostat
Used to define the 3-way control valve used in
the system
0 = 2-wire/spring return or 3-wire/SPST valve;
1 = 3-wire/SPDT valve
6B4
-
0~1
0
SPDT valve preferred
Synchronization from pump P2
0 = Pump 2 runs in parallel with pump 1
1 = Continuous operation of pump 2
6B5
-
0~1
0
OFF: With a bivalent heating system, when 5B is set to 3,
P2 and mixing valve control remain active
ON: P2 switches off during hot water generation
Used if a domestic hot water tank is connected
to the system
0 = Domestic hot water tank connected
1 = No domestic hot water tank connected
6B8
-
0~1
0
For activating zone 1 operation
0 = Zone 1 activated
1 = Zone 1 deactivated
6B9
-
0~1
0
Must be set to ON if the heat pump is only used for
domestic hot water generation.
For activating zone 2 operation
0 = Zone 2 deactivated
1 = Zone 2 activated
6BA
-
0~1
0
e.g., when using radiators and underfloor heating
P1 pump operation for heating
0 = P1 runs continuously
1 = At an outdoor temperature of over 20°C,
P1 switches off
6D0
-
0~1
0
ON = From an outdoor temperature of over 20°C, the
pump switches itself off.
The temperature can be changed using DN code 9E.
Pump P1 at normal output when thermo off for
long periods.
0 = No operation
1 = Normal output
6D1
-
0~1
0
Used to activate the backup heater of the hydro
unit
0 = Backup heater activated
1 = Backup heater deactivated
6D2
-
0~1
0
Backup heater in the Hydrobox: TB03 connection
3, 6, or 9 kW output
For activating e-heating in the domestic hot
water tank
0 = E-heating elements in the domestic hot
water tank activated
1 = E-heating elements in the domestic hot
water tank deactivated
6D3
-
0~1
0
TB02 connection
Should always be set to OFF
For activating booster heating
0 = External booster heating output activated
1 = External booster heating output deactivated
6D4
-
0~1
0
When the outdoor temperature drops below -20°C,
the contact at connection CN23 / 5+6 (230 V/1 A) is
activated.
Used to activate the automatic restart following a
power blackout
0 = Automatic restart deactivated
1 = Automatic restart activated
28
-
0~1
1
P1 pump operation for hot water
0 = P1 only runs during hot water preparation
1 = P1 runs continuously
5A
-
0~1
0
Synchronizes pump 1 with outdoor unit
during hot water preparation
FUNCTION CODES
Содержание ESTIA R32 HWT-1101F21MT6W-E
Страница 1: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...
Страница 3: ...8 11 14 16 h LI 1 Ph LI 1 Ph LI h LI 1 Ph LI 1 Ph LI 3 Ph 1 Ph 3 Ph 3 Ph h h 1 Ph 3 Ph 3 Ph ...
Страница 8: ......
Страница 26: ...26 I TOSHIBA 26 I TOSHIBA SCHEMA 1 0 ...
Страница 27: ...TOSHIBA I 27 TOSHIBA I 27 SCHEMA 1 1 ...
Страница 28: ...28 I TOSHIBA 28 I TOSHIBA SCHEMA 2 0 ...
Страница 29: ...TOSHIBA I 29 TOSHIBA I 29 SCHEMA 2 1 ...
Страница 30: ...30 I TOSHIBA 30 I TOSHIBA SCHEMA 3 0 ...
Страница 31: ...TOSHIBA I 31 TOSHIBA I 31 SCHEMA 3 1 ...
Страница 32: ...32 I TOSHIBA 32 I TOSHIBA SCHEMA 4 0 ...
Страница 33: ...TOSHIBA I 33 TOSHIBA I 33 SCHEMA 4 1 ...
Страница 34: ...34 I TOSHIBA 34 I TOSHIBA SCHEMA 5 0 ...
Страница 35: ...TOSHIBA I 35 TOSHIBA I 35 SCHEMA 6 0 ...
Страница 36: ...36 I TOSHIBA 36 I TOSHIBA SCHEMA 7 0 ...
Страница 37: ...TOSHIBA I 37 TOSHIBA I 37 WIRING DIAGRAM 230 V ...
Страница 38: ...38 I TOSHIBA 38 I TOSHIBA WIRING DIAGRAM 400V ...
Страница 41: ...APPENDIX R32 VERSION 1 0 Manual for ESTIA air to water heat pump ...