e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 110
483
Laser
Pre-running rotation of
polygonal motor
ALL
0
<0-2>
SYS
Sets whether or not
switching the polygonal
motor from the standby
rotation to the normal
rotation when the origi-
nal is set on the RADF
or the platen cover is
opened.
0: Valid (when using
RADF and the origi-
nal is set manually)
1: Invalid
2: Valid (when using
RADF only)
1
484
Laser
Polygonal motor rotational
status switching at the Auto
Clear Mode
ALL
0
<0-1>
SYS
Sets whether or not
switching the polygonal
motor from the normal
rotation to the standby
rotation at the Auto
Clear Mode.
0: Valid
1: Invalid
1
485
Laser
Rotational status of polygo-
nal motor on standby
ALL
JPN: 1
Others: 0
<0-1>
SYS
Sets the rotational sta-
tus of polygonal motor
on standby.
0: Rotated (The rota-
tional speed is set at
08-490.)
1: Stopped
1
486
Laser
Timing of auto-clearing of
polygonal motor pre-run-
ning rotation
ALL
0
<0-2>
SYS
Switches the polygonal
motor to the standby
rotation when a certain
period of time has
passed from the pre-
running. At this code,
the period to switch the
status to the standby
rotation is set.
0: 15 sec.1: 30 sec.
2: 45 sec.
*
This setting is effec-
tive when “0” or “2”
is set at 08-483.
1
488
Laser
Setting of polygonal motor
type
ALL
0
<0-3>
M
Set the type of polygo-
nal motor.
0: 2-clock type
1: 3-clock type
2: 4-clock type
3: 4-clock type
1
489
Laser
Polygonal motor rotation
number on standby
ALL
5
<0-5>
M
0: 38,090.55 rpm
1: 35,000 rpm
2: 30,000 rpm
3: 25,000 rpm
4: 20,000 rpm
5: 10,000 rpm
1
490
Laser
Polygonal motor rotation in
the energy saving mode
ALL
0
<0-1>
M
0: Stopped
1: 10,000 rpm
1
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
04/09