© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 105
2
414
Devel-
oper
Toner density life correc-
tion switching
ALL
0
<0-7>
M
0: Unchanged (Default)
1: Approx. 0.3 wt%
higher
2: Approx. 0.6 wt%
higher
3: Approx. 0.9 wt%
higher
4: Approx. 0.2 wt%
lower
5: Approx. 0.4 wt%
lower
6: Approx. 0.6 wt%
lower
7: Approx. 0.9 wt%
lower
1
417
Fuser
Pre-running time for first
printing
(Thick paper 3)
ALL
10
<0-15>
M
0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
424-0
Fuser
Temperature
drop switching
time setting in
ready status
(Center ther-
mistor)
The first
drop
ALL
15
<2-60>
M
This code is valid only
when “20” is set to 08-
886.
Setting value x 1 min.:
from 2 to 60 min. later
4
424-1
The sec-
ond drop
ALL
15
<2-60>
M
4
424-2
The third
drop
ALL
15
<2-60>
M
4
424-3
The fourth
drop
ALL
15
<2-60>
M
4
425-0
Fuser
Temperature
drop switching
time setting in
ready status
(Side ther-
mistor)
The first
drop
ALL
15
<2-60>
M
4
425-1
The sec-
ond drop
ALL
15
<2-60>
M
4
425-2
The third
drop
ALL
15
<2-60>
M
4
425-3
The fourth
drop
ALL
15
<2-60>
M
4
433-0
Fuser
Temperature
control lower
limit
(Plain paper/
at ordinary
temperature)
Center
thermistor
ALL
7
<0-12>
M
0: 130°C 1: 135°C
2: 140°C 3: 145°C
4: 150°C 5: 155°C
6: 160°C 7: 165°C
8: 170°C 9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
433-1
Side ther-
mistor
ALL
5
<0-12>
M
4
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
04/09