e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
5 - 110
15)Poor image transfer
Fig. 5-15
Defective area
Step
Check items
Prescription
Paper
1
Is the paper in the drawer or LCF/
PFP curled?
Reinsert the paper with the reverse
side up or change the paper.
2
Is the paper in the drawer or LCF
damp?
Avoid storing paper in damp place.
3
Is the paper type corresponding to its
mode?
Select the proper mode.
4
Using the recommended paper?
Use the recommended paper.
Transfer charger
5
Is the transfer charger case dirty?
Clean the transfer charger case.
6
Is the transfer charger wire dirty?
Clean the transfer charger wire.
Registration roller
7
Is there any abnormality related to
the registration roller or with the roller
itself?
Clean the roller if it is dirty. Securely
attach the springs if they are
detached. Replace the clutch if it is
defective. Adjust the rotation speed
of the roller.
High-voltage transformer
(Transfer charger)
8
Is the high-voltage transformer out-
put defective?
Adjust the output, or replace the
transformer.
Feeding direction