© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 125
2
801-0
Fuser
Temperature
control lower
limit
(Thick paper
1)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
801-1
Side
thermistor
ALL
6
<0-12>
M
4
802-0
Fuser
Temperature
control lower
limit
(Thick paper
2)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
802-1
Side
thermistor
ALL
9
<0-12>
M
4
803-0
Fuser
Temperature
control lower
limit
(Thick paper
3)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
803-1
Side
thermistor
ALL
10
<0-12>
M
4
804-0
Fuser
Temperature
control lower
limit
(Envelope)
Center
thermistor
ALL
8
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
804-1
Side
thermistor
ALL
10
<0-12>
M
4
805
Charger
Main charger bias correc-
tion
(Text/Photo/OHP film)
PRT
98
<0-255>
M
Corrects the value of
the main charger bias
adjustment (05-210).
1
806
Charger
Main charger bias correc-
tion
(Toner Saving Mode/OHP
film)
PRT
98
<0-255>
M
1
807
Charger
Main charger bias correc-
tion
(Text/Photo/OHP film)
PPC
98
<0-255>
M
1
808
Charger
Main charger bias correc-
tion
(Text/OHP film)
PPC
98
<0-255>
M
1
809
Charger
Main charger bias correc-
tion
(Photo/OHP film)
PPC
98
<0-255>
M
1
826
Charger
Main charger bias correc-
tion
(Toner saving mode)
PRT
128
<0-255>
M
1
830
Transfer
Transfer transformer DC
correction (C)
ALL
128
<0-255>
M
Corrects the value of
the transfer trans-
former DC output
adjustment (05-221).
1
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
05/05