© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 111
2
491
Transfer
Transfer charger bias cor-
rection (H) at duplexing
ALL
149
<0-255>
M
Corrects the transfer
charger bias output
value of the leading
edge area of paper at
duplexing.
1
492
Transfer
Transfer charger bias cor-
rection (C) at duplexing
ALL
139
<0-255>
M
Corrects the transfer
charger bias output
value of the center area
of paper at duplexing.
1
493
Transfer
Transfer charger bias cor-
rection (L) at duplexing
ALL
128
<0-255>
M
Corrects the transfer
charger bias output
value of the trailing
edge area of paper at
duplexing.
1
502
Image
Error diffusion and dither
setting at photo mode
PPC
1
<0-1>
SYS
Sets the image repro-
duction method at
photo mode.
0: Error diffusion
1: Dither
1
503
User
interface
Default setting of density
adjustment
PPC
0
<0-1>
SYS
0: Automatic
1: Manual (Center)
1
508
Image
Custom Mode setting
PPC
0
<0-3>
SYS
0: Not used
1: Custom Mode 1
when Text/Photo is
set as a base
2: Custom Mode 2
when Text is set as
a base
3: Custom Mode 3
when Photo is set
as a base
1
509
Image
Error diffusion and dither
setting at a photo mode
(Custom Mode)
PPC
1
<0-1>
SYS
Switches the image
processing method
when Custom Mode 3
is set.
0: Error diffusion
1: Dither
1
515
Fuser
Temperature setting of
warming-up
(Center thermistor)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
516
Fuser
Temperature setting of
warming-up
(Side thermistor)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
Setting mode (08) <e-STUDIO200L/230/230L/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-