© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 183
2
486
Laser
Timing of auto-clearing of
polygonal motor pre-run-
ning rotation
ALL
0
<0-2>
SYS
Switches the polygonal
motor to the standby
rotation when a certain
period of time has
passed from the pre-
running. At this code,
the period to switch the
status to the standby
rotation is set.
0: 15 sec.1: 30 sec.
2: 45 sec.
*
This setting is effec-
tive when “0” or “2”
is set at 08-483.
1
488
Laser
Setting of polygonal motor
type
ALL
0
<0-3>
M
Set the type of polygo-
nal motor.
0: 2-clock type
1: 3-clock type
2: 4-clock type
3: 4-clock type
1
489
Laser
Polygonal motor rotation
number on standby
ALL
5
<0-5>
M
0: 38,090.55 rpm
1: 35,000 rpm
2: 30,000 rpm
3: 25,000 rpm
4: 20,000 rpm
5: 10,000 rpm
1
490
Laser
Polygonal motor rotation in
the energy saving mode
ALL
0
<0-1>
M
0: Stopped
1: 10,000 rpm
1
491
Transfer
Transfer charger bias cor-
rection (H) at duplexing
ALL
149
<0-255>
M
Corrects the transfer
charger bias output
value of the leading
edge area of paper at
duplexing.
1
492
Transfer
Transfer charger bias cor-
rection (C) at duplexing
ALL
139
<0-255>
M
Corrects the transfer
charger bias output
value of the center area
of paper at duplexing.
1
493
Transfer
Transfer charger bias cor-
rection (L) at duplexing
ALL
128
<0-255>
M
Corrects the transfer
charger bias output
value of the trailing
edge area of paper at
duplexing.
1
502
Image
Error diffusion and dither
setting at photo mode
PPC
1
<0-1>
SYS
Sets the image repro-
duction method at
photo mode.
0: Error diffusion
1: Dither
1
503
User
interface
Default setting of density
adjustment
PPC
0
<0-1>
SYS
0: Automatic
1: Manual (Center)
1
Setting mode (08) <e-STUDIO202L/203L/232/233/282/283>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
07/11