[Antenna Position]:
Selects the actual RF antenna position.
This setting is required for properly performing an RFID calibration.
This parameter is exclusive for the B-EX4T1-G/T (203dpi/305dpi).
Default
FRONT
Options
FRONT, CENTER, REAR
[Retry] Group
[Retry Position Adjustment]:
Sets the amount the printer feeds the RFID label forward or backward to retry data write.
Default
0 mm
Range
-99 to 99 mm
[Issue Retry Labels]:
Sets the number of RFID labels to be issued for retry.
Default
3 labels
Range
0 to 255 labels
[Read Retry Count]:
Sets the max. number of times reading one RFID tag is retried.
Default
5 times
Range
0 to 255 times
[Read Retry Timeout]:
Sets the timeout value for retry to read one RFID tag.
Default
4.0 sec
Range
0.0 to 9.9 sec
[Write Retry Count]:
Sets the number of times writing data to one RFID tag is retried.
Default
5 times
Range
0 to 255 times
[Write Retry Timeout]:
Sets the timeout value for retry to write data to one RFID tag.
Default
2.0 sec
Range
0.0 to 9.9 sec
[Head Up Action] Group
[Head Up Action]:
Selects whether or not a head up action is performed during a reverse feed of an RFID tag.
This parameter is exclusive for the B-EX4T1-T JP (305dpi).
Default
MODE 1
Range
MODE 1, MODE 2