H7 ASD Operation Manual
73
R Input Terminal Delay
Program
⇒
Terminal Selection Parameters
⇒
Input Terminal Delays
⇒
R
This parameter delays the response of the drive to any change in the R terminal
input by the programmed value (see waveforms at
F140
).
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
Direct Access Number — F141
Parameter Type — Numerical
Factory Default — 8.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
ST Input Terminal Delay
Program
⇒
Terminal Selection Parameters
⇒
Input Terminal Delays
⇒
ST
This parameter delays the response of the drive to any change in the ST
terminal input by the programmed value (see waveforms at
F140
).
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
Direct Access Number — F142
Parameter Type — Numerical
Factory Default — 8.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
RES Input Terminal Delay
Program
⇒
Terminal Selection Parameters
⇒
Input Terminal Delays
⇒
RES
This parameter delays the response of the drive to any change in the RES
terminal input by the programmed value (see waveforms at
F140
).
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
Direct Access Number — F143
Parameter Type — Numerical
Factory Default — 8.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
S1 – S4 Input Terminal Delay
Program
⇒
Terminal Selection Parameters
⇒
Input Terminal Delays
⇒
S1 – S4
This parameter delays the response of the drive to any change in the S1 – S4
terminal input by the programmed value (see waveforms at
F140
).
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
Direct Access Number — F144
Parameter Type — Numerical
Factory Default — 8.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
S5 – S16 Input Terminal Delay
Program
⇒
Terminal Selection Parameters
⇒
Input Terminal Delays
⇒
S5 – S16
This parameter delays the response of the drive to any change in the S5 – S16
terminal input by the programmed value (see waveforms at
F140
).
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
Direct Access Number — F145
Parameter Type — Numerical
Factory Default — 8.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
www
. ElectricalPartManuals
. com
Содержание Adjustable Speed Drive H7 Series
Страница 198: ...H7 ASD Operation Manual Appendix A 191 Figure 23 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 199: ...192 Appendix A H7 ASD Operation Manual Figure 24 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...
Страница 201: ...194 Appendix A H7 ASD Operation Manual Figure 26 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...