Greensmaster 3250−D
Page 5 − 4
Electrical System (Rev. C)
Troubleshooting
CAUTION
Remove all jewelry, especially rings and
watches, before doing any electrical trouble-
shooting or testing. Disconnect the battery
cables unless the test requires battery voltage.
For effective troubleshooting and repairs, you must
have a good understanding of the electrical circuits and
components used on this machine (see Wiring Sche-
matics section of this chapter).
If the machine has any interlock switches by−passed,
they must be reconnected for proper troubleshooting
and safety.
Starting Problems
Problem
Possible Causes
Starter solenoid clicks, but starter will not crank
(if solenoid clicks, problem is not in safety interlock
system).
Battery charge is low.
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Wiring at starter is faulty.
Starter solenoid is faulty.
Starter mounting bolts are loose or not supplying a
sufficient ground for solenoid.
Starter is faulty and causing an incomplete circuit for
the solenoid.
Relay R4 or R8 has intermittent ground.
Nothing happens when start attempt is made.
Battery is dead.
Wiring to the start circuit (see Wiring Schematics)
components is loose, corroded, or damaged.
Battery cables are loose or corroded.
Battery ground to frame is loose or corroded.
Fuselink 2 is open.
Fuse block is faulty.
10 ampere fuse to the run relay is loose or blown.
Diode D6, safety relay, or start relay is faulty.
15 ampere fuse to the ignition switch is loose or blown.
The ignition switch is faulty.
Starter solenoid is faulty.
High temperature relay, run relay, and/or high
temperature switch are faulty.
Neutral sensor is out of adjustment or faulty.
The ETR solenoid is faulty.
Содержание Greensmaster 3250-D 04383
Страница 2: ...Greensmaster 3250 D This page is intentionally blank...
Страница 4: ...Greensmaster 3250 D This page is intentionally blank...
Страница 10: ...0 09375 Rev H Greensmaster 3250 D Page 2 2 Product Records and Maintenance Equivalents and Conversions...
Страница 38: ...Greensmaster 3250 D Page 3 24 Engine This page is intentionally blank...
Страница 40: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 2 This page is intentionally blank...
Страница 119: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 81 This page is intentionally blank Hydraulic System...
Страница 141: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 103 This page is intentionally blank Hydraulic System...
Страница 149: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 111 This page is intentionally blank Hydraulic System...
Страница 200: ...Greensmaster 3250 D Page 6 16 Chassis Rev D This page is intentionally blank...
Страница 238: ...Greensmaster 3250 D SPA and 4 Bolt Cutting Units Rev A Page 7 38 This page is intentionally blank...
Страница 258: ...Greensmaster 3250 D Dual Point Adjust Cutting Units Rev D Page 7 1 20 This page is intentionally blank...
Страница 264: ...Greensmaster 3250 D Dual Point Adjust Cutting Units Rev D Page 7 1 26 This page is intentionally blank...
Страница 282: ...Greensmaster 3250 D Page 8 2 Electrical Diagrams This page is intentionally blank...
Страница 295: ...Rev H Page 8 15 This page is intentionally blank...
Страница 299: ...Rev H Page 8 19 Wiring Diagram Serial Number Between 210000000 and 230000600 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 301: ...Rev H Page 8 21 Wiring Diagram Serial Number Between 230000600 and 240999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 303: ...Rev H Page 8 23 Wiring Diagram Serial Number Between 250000000 and 250999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 305: ...Rev H Page 8 25 Wiring Diagram Serial Number Between 260000001 and 260999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 306: ...Rev H Page 8 26 Electrical Harness Drawing Serial Number Above 270000000 Greensmaster 3250 D...
Страница 307: ...Rev H Page 8 27 Wiring Diagram Serial Number Above 270000000 Greensmaster 3250 D...
Страница 308: ...Rev H Page 8 28 This page is intentionally blank...