Greensmaster 3250--D
Hydraulic System (Rev. I)
Page 4 -- 15
Traction Forward and Reverse
Forward
The hydrostat (P3) is driven directly by the engine. The
traction circuit of the hydraulic system acts essentially
as a closed loop. Taking its suction directly from the re-
turn side of the wheel motors of the traction circuit, the
hydrostat supplies oil flow to the wheel motors through
the supply side of the traction circuit.
With the engine running and traction pedal in the neutral
position, the hydrostat supplies no flow to the wheel mo-
tors. When the traction pedal is pressed to the forward
position, the linkage from the pedal positions the swash
plate in the hydrostat so oil flows out the bottom port of
the pump. Oil flow out of the bottom port goes to the
wheel motors and turns them in the forward direction.
Oil flowing out of the wheel motors returns to the top port
of the hydrostat and is continuously pumped out the bot-
tom port.
Hydraulic oil is supplied to the traction circuit from the
gear pump (P2) though the steering control valve and
back through the charge circuit check valves. This oil re-
places oil losses from flow through the internal case
drain, internal bleed valve, and small amounts of leak-
age. Charge circuit pressure is maintained by the
charge relief valve (R4) that is attached to the hydrostat
back plate.
Reverse
The traction circuit operates essentially the same in re-
verse as it does in the forward direction. However, the
flow through the circuit is reversed.
With the engine running and traction pedal in the neutral
position, the hydrostat supplies no flow to the wheel mo-
tors. When the traction pedal is pressed to the reverse
position, the linkage from the pedal positions the swash
plate in the hydrostat so oil flows out the top port of the
pump. Oil flow out of the top port goes to the wheel mo-
tors and turns them in the reverse direction.
Oil flowing out of the wheel motors returns to the bottom
port of the hydrostat and is continuously pumped out the
bottom port.
The charge circuit functions the same in reverse as it did
in the forward direction.
Traction Circuit Cooling
The traction circuit is cooled by a bleed off circuit in the
hydrostat. The bleed off circuit includes an internal bleed
valve which allows about 1 GPM of hydraulic oil to pass
from the reverse side of the hydrostat while operating
the traction unit in the forward direction. The internal
bleed valve closes when operating the traction in the re-
verse direction.
Note:
The bleed valve threads into the hydrostat back
plate. Access to the bleed valve requires removal of the
back plate from the hydrostat.
Hydraulic System
Содержание Greensmaster 3250-D 04383
Страница 2: ...Greensmaster 3250 D This page is intentionally blank...
Страница 4: ...Greensmaster 3250 D This page is intentionally blank...
Страница 10: ...0 09375 Rev H Greensmaster 3250 D Page 2 2 Product Records and Maintenance Equivalents and Conversions...
Страница 38: ...Greensmaster 3250 D Page 3 24 Engine This page is intentionally blank...
Страница 40: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 2 This page is intentionally blank...
Страница 119: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 81 This page is intentionally blank Hydraulic System...
Страница 141: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 103 This page is intentionally blank Hydraulic System...
Страница 149: ...Greensmaster 3250 D Hydraulic System Rev I Page 4 111 This page is intentionally blank Hydraulic System...
Страница 200: ...Greensmaster 3250 D Page 6 16 Chassis Rev D This page is intentionally blank...
Страница 238: ...Greensmaster 3250 D SPA and 4 Bolt Cutting Units Rev A Page 7 38 This page is intentionally blank...
Страница 258: ...Greensmaster 3250 D Dual Point Adjust Cutting Units Rev D Page 7 1 20 This page is intentionally blank...
Страница 264: ...Greensmaster 3250 D Dual Point Adjust Cutting Units Rev D Page 7 1 26 This page is intentionally blank...
Страница 282: ...Greensmaster 3250 D Page 8 2 Electrical Diagrams This page is intentionally blank...
Страница 295: ...Rev H Page 8 15 This page is intentionally blank...
Страница 299: ...Rev H Page 8 19 Wiring Diagram Serial Number Between 210000000 and 230000600 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 301: ...Rev H Page 8 21 Wiring Diagram Serial Number Between 230000600 and 240999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 303: ...Rev H Page 8 23 Wiring Diagram Serial Number Between 250000000 and 250999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 305: ...Rev H Page 8 25 Wiring Diagram Serial Number Between 260000001 and 260999999 Greensmaster 3250 D GLOW PLUG CONTROLLER...
Страница 306: ...Rev H Page 8 26 Electrical Harness Drawing Serial Number Above 270000000 Greensmaster 3250 D...
Страница 307: ...Rev H Page 8 27 Wiring Diagram Serial Number Above 270000000 Greensmaster 3250 D...
Страница 308: ...Rev H Page 8 28 This page is intentionally blank...