Charging the Battery
WARNING
Charging the battery produces gasses that
can explode.
Never smoke near the battery and keep sparks
and flames away from battery.
Important:
Always keep the battery fully charged
(1.265 specific gravity) to prevent battery damage
when the temperature is below 0°C (32°F).
1.
Remove the battery from the chassis; refer to
Removing the Battery (page 36)
.
2.
Check the electrolyte level.
3.
Ensure that the filler caps are installed on the
battery.
4.
Charge the battery for 1 hour at 25 to 30 A or 6
hours at 4 to 6 A.
5.
When the battery is fully charged, unplug the
charger from the electrical outlet, and disconnect
the charger leads from the battery posts (
6.
Install the battery onto the machine and connect
the battery cables; refer to
(page 37)
.
Note:
Do not run the machine with the battery
disconnected; electrical damage may occur.
g000538
Figure 50
1.
Positive battery post
3.
Red (+) charger lead
2.
Negative battery post
4.
Black (-) charger lead
Installing the Battery
Install the battery as shown in
g030989
Figure 51