Changing the Engine Oil
Service Interval:
After the first 8 hours
Every 100 hours
Note:
Dispose of the used oil at a recycling center.
1.
Park the machine so that the drain side is slightly
lower than the opposite side to assure the oil
drains completely.
2.
Disengage the PTO, move the motion-control
levers to the N
EUTRAL
-
LOCK
position, and
engage the parking brake.
3.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
4.
Change the engine oil as shown in
.
g031514
g027660
Figure 40
5.
Slowly pour approximately 80% of the specified
oil into the filler tube and slowly add the
additional oil to bring it to the
Full
mark (