Step 5.6:
Check for continuity between the following pairs of locations:
Location
Harness
Connector
Pin
Connector Graphic
1
Battery
adapter
P04
POS
POS
NEG
+
_
P1 P2
S1 S2
2
Battery
adapter
P26
A
A
B
1
Battery
adapter
P04
NEG
POS
NEG
+
_
P1 P2
S1 S2
2
Battery
adapter
P26
B
A
B
Pass
Circuit continuity tested good at the listed locations. Go to Step 6 and follow the steps listed.
Fail
For those items that failed, repair or replace worn or damaged parts as required. Go to
Returning the Equipment to Service (page 19)
and follow the steps listed.
Step 6:
Battery Internal Contactor Qualifier Fault.
May require Li+ diagnostic wire harness, Toro part number 120-6339, to be installed for consulting with your Toro Service
Representative. Refer to
Installing the Li+ Diagnostic Wire Harness (page 8)
as needed.
Note:
The battery diagnostic wire harness is configured with extra wire length, and jumper capability for troubleshooting
requirements. The diagnostic wire harness has the ability for direct Li+ battery pack CAN communication while using
Toro DIAG interface.
Note:
Do not replace the battery pack unless the fault repeats and you have talked with your Toro Service Representative.