GIRE-097-2-2
9
If any abnormality is found in the equipment during chemical
cleaning, immediately stop operation and check it.
If chemical is injected forcibly directly with the chemical feed pump
or by any other means, the internal pressure of the elements will
increase and the elements will get damaged. Be sure to inject
chemical with the pressure of lower than 10 kPa (100 mbar).
When injecting the chemical agents at the chemical cleaning,
please confirm beforehand that the modules are completely
submerged in the liquid and the liquid level of the membrane
submerged tank is higher by more than 300 mm than the top of the
module.
Please store the chemical agents in a dark cold place free from
direct sunlight.
Please use the appropriate tank or the container, for storing the
chemical agent, made of the material having enough corrosion
resistance to each chemical agent.
Don't mix sodium hypochlorite with acids, including oxalic acid or
citric acid; otherwise toxic chlorine gas is generated.
Don't mix sodium hypochlorite with heavy metals.
Please stop the scouring air during the chemical cleaning, or the
membrane elements might be damaged.
WARNING
!
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
WARNING
!
WARNING
!
CAUTION
!