multiSwitch – user manual
© TOPEX 2008 84
8.5.5 The "Access Out" option
The "
Access Out
" option stores the destination IPs for each outgoing client class and controls
the outgoing traffic in TOPEX multiSwitch.
Access Out is used only for IP calls (SIP/H323). In Access Out you enter information about the
call destination.
For configuration, press the "
New Rule
" button, to enter records. A new window will appear,
with the configuration options:
Figure 39 – The "Access Out" option
The user defines the following options:
Class –
the source name of the client class;
Host –
the destination IP;
Port –
port used for signaling (for example
1720
for H323 or
5060
for SIP);
Protocol –
the signaling protocol used (can be
SIP
or
H323
);
Transport
– The transport protocol used
Media Parameters
– the media parameters used
After configuring them, the records will be displayed as follows, and you will be able to edit
or delete them by using the "
Edit"
and "
Delete"
options
in the
Action
region:
Figure 40 – Displaying the records in the "Access Out" menu