24
Potentiometer A
is used to adjust the stall force the gate opener. Turn the potentiometer clockwise to increase
the stall force, and turn it counter-clockwise to decrease the stall force.
Potentiometer B
is used to adjust the auto close time of the gate opener. Turn the potentiometer clockwise to
increase the auto close time, and turn it counter-clockwise to decrease the auto close time. The auto close time
can be adjusted gradually from 3 to 120 seconds.
Potentiometer C
is used to adjust the soft stop period of the gate opener. Turn the potentiometer clockwise to
increase the soft stop period, and turn it counter-clockwise to decrease the soft stop period. The soft stop period
can be adjusted gradually from 1 to 5 seconds.
Maintenance
Warning:
Disconnect power before servicing.
1. Using a clean, dry cloth to wipe the gate opener shaft, and then apply a silicone spray to reduce its friction. In
cold climates where temperatures reach 1°C (30°F) or less, spray silicone on the actuator every 4~6 weeks to
prevent freeze up.
2. Regularly check gate hinges to make sure gate is swinging smoothly and freely. Grease hinges if needed.
3. Check your installation periodically, as hardware and posts will shift. Brackets may need to be adjusted or
hardware may need to be tightened.
4. Maintain the area around your gate. Keep the areas free of objects that can prevent the gate swinging freely.
NOTES:
1. Inspection and service should always be performed anytime a malfunction is observed or suspected.
2. It is suggested that while at the site voltage readings be taken at the operator. Using a Digital Voltmeter, verify
that the incoming voltage to the opener it is within ten percent of the opener’s rating.
3. Refer to the instructions on how to check gate force and sensitivity adjustments.
Trouble Shooting
Have a multi-meter to check voltage and continuity. Use caution when checking high voltage terminals.
Symptom
Possible Solution(s)
The opener does not
run. Power LED does
not ON. The UPS01
has been connected
to the gate opener
control box.
1. Make sure the connection between the UPS01 and control box is correct and
fastening.
2. Make sure the UPS01 power supply has been plugged into the AC main socket
or the batteries (2*12V batteries connected in series) have been connected to the
UPS01 well.
3. Battery is over-discharge if you only use batteries with the UPS01 to power up
the gate opener. The voltage of the battery should above 22V to make the gate
opener work normally. Please wait the battery to be charged above 22VDC.
4. Check the output of UPS01. If the output of UPS01 is measured below 21VDC
and the voltage of the batteries is above 22VDC or the power cord has been
plugged into the socket well, then the UPS01 is defective.
5. Check the fuse in the control board. Replace the fuse if it was burnt out.