16
the control box refer to step 1 in this chapter. And then you can connect 2 PCS 12VDC batteries in series and
then connect it to the UPS-01 power supply.
Power Mode 3. Use the batteries as the power source, only use the solar
panel to charge the batteries
If the AC electricity is not available, then you can choose the batteries as the power source and use the solar
panel to charge the batteries. The capacity of the batteries should be at least 12AH and the power of the solar
panel should be at least 20W in this situation. The gate opener can run for 10 cycles per day without connecting
any other accessories except push button & alarm lamp if the local average sunshine time is more than 6 hours
per day. The power of the solar panel and the capacity of the batteries should be enlarged if the local average
sunshine time is less than 6 hours per day or using one of the accessories (photocell, external receiver, exit
wand and keypad). Please provide us with more details of the local sunshine condition and accessories needs
which we can calculate the configuration of the solar panel and the batteries. Please connect the UPS-01 power
supply & batteries & the solar panels refer to the following wiring diagram. You can leave the power cord Not
Plugged in this situation.