23
DIP Switch #1: Select push/pull to open
If the gate opens into the property (
pull to open
), the DIP Switch is set to
OFF
(factory default setting). If your
gate opens out from the property (
push to open
) the DIP Switch must be set to the
ON
position.
Factory default setting is
OFF
.
DIP Switch #2: Auto close function enabled/disabled
ON
– Auto close function
enabled
OFF
– Auto close function
disabled
Set the switch #2 to ON to enable the auto close function. Factory default setting is
OFF
.
Important Note: When the auto close function is enabled, the photocell sensor is highly
recommended to be installed with the gate opener for safety.
DIP Switch #3: Photocell function enabled/disabled
ON
– Photocell function
enabled
OFF
– Photocell function
disabled
You must set the switch #3 to ON to enable the photocell function if you want to use the photocell with the gate
opener. Factory default setting is
OFF
2. Potentiometers
There are 3 potentiometers located in the control board. They are used to adjust the stall force, auto-close time
and soft stop period.