1.
Insert the bolts through the holes of post bracket and post pivot
bracket as shown. Place washers and nuts on the bottom of the
bolts and hand tighten.
2.
Attach the gate bracket and post bracket assy. to the opener by
inserting a clevis pin. Secure the clevis pins using the hairpin clips.
3.
Insert the release key, and turn the key 90° clockwise. This releases the motor and allows the push-pull rod to
be manually extended and retracted. To restore normal operation, turn the key 90° counterclockwise.
4. With the opener fully retracted and with the gate in the fully open position (for Pull-to-Open
installation)
, place the opener with the Post Bracket Assy. and Gate Bracket on the gate post and the gate.
While holding the gate opener in the level position, temporarily secure it with two C-clamps.
5.
Make sure that there is a minimum clearance of 2.5cm between the gate and the opener and that the opener
and the Post Pivot Bracket are not binding in both the gate-open and gate-closed positions. If there is not at
least 2.5cm of clearance or if the opener and the Post Pivot Bracket are binding, rotate the Post Pivot Bracket
and/or move the Post Bracket Assy. to obtain the minimum clearance and eliminate the binding.