25
6. Check the control board. Replace the control board if necessary.
Gate moves a little
and then reverse or
stop
1. The selected force is too small to move the gate. Turn the Potentiometer
clock-wise to increase the force.
2. Disconnect the gate from the gate operator and check that the gate slides freely
without any binding.
Gate opener does not
run when you press
the remote control
1. Make sure the remote has been programmed to the control board before using.
2. The battery of the remote may be exhausted. Replace the battery and try it
again.
3. Check if the limit switch is broken. Remove the BLUE&GREEN&YELLOW wires
of the arm from the control board and use a jumper wire to short the
ULT&COM&DLT terminals of the control board which for connecting the three
wires and then try it again. The limit switch of the arm is faulty if the arm could run
normally.
4. The control board could be faulty. Replace the control board as necessary.
Gate can open but
does not close
1. Make sure the connection of the photocell beam is not blocked if the photocell is
used.
2.
Check
if
the
closed
limit
switch
is
broken.
Remove
the
BLUE&GREEN&YELLOW wires of the arm from the control board and use a
jumper wire to short the ULT&COM&DLT terminals of the control board which for
connecting the three wires and then try it again. The limit switch of the arm is faulty
if the arm could run normally.
3. The control board could be faulty. Replace the control board as necessary.
Gate
automatically
opens, but does not
automatically close
1. Setting of DIP switch #1 would be wrong. Please set the dip switch correctly
according to the push/pull to opener installation of the gate opener.