3-4
3 ANGLE MEASUREMENT
3.6 Buzzer Sounding for Horizontal Angle 90° Increments
When the horizontal angle falls in the range of less than ± 1° of 0°, 90°, 180° or 270°, the buzzer
sounds. Buzzer stops only when the horizontal angle is adjusted to 0°00’00”, 90°00’00”, 180°00’00” or
270°00’00”.
This setting is not memorized after powering off.
Refer to 17 “SELECTING MODE” to set the initial
setting (memorized after powering off).
Make sure the mode is Angle measurement.
7
Recollimate target A using the horizontal clamp
and tangent screw, and press the
{F3}
(REL)key.
Collimate A
{F3}
8
Recollimate target B using the horizontal clamp
and tangent screw, and press the
{F4}
(HOLD)
key.
Collimate B
{F4}
9
Repeat
7
to
8
to measure the desired number of
repetitions.
[Example] 4 measurement
10
To return to the normal angle mode, press the
{F2}
(V/H) key or
{ESC}
key.
{ESC}
or
{F2}
11
Press the
{F3}
(YES) key.
{F3}
Horizontal angle can be accumulated up to (3600°00'00" – minimum reading) (horizontal angle right).
In case of 5 second reading, horizontal angle can be accumulated up to +3599°59'55".
Error will be displayed when the results differ from first measurement by more than ±30".
Operating procedure
Operation
Display
1
Press the
{F4}
(
↓
) key twice to get the function
on page 3.
{F4}
twice
2
Press the
{F1}
(H-BZ) key.
The data previously set is shown.
{F1}
REP-ANGLE COUNT[ 1]
Ht: 45°10'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 2]
Ht: 90°20'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REP-ANGLE COUNT[ 4]
Ht: 180°40'00"
Hm: 45°10'00"
0SET V/H REL HOLD
REPETITION ANGLE
Exit
>OK?
--- --- [YES][NO]
V :
90°10'20"
HR:
170°30'20"
0SET HOLD HSET P1
↓
V :
90°10'20"
HR:
170°30'20"
0SET HOLD HSET P1
↓
H-BZ R/L CMPS P3
↓
H-ANGLE BUZZER [OFF]
[ON] [OFF] --- ENTER