1-9
1 NOMENCLATURE AND FUNCTIONS
1.6 Serial signal RS-232C connector
The serial signal connector is used for connecting the GM with a computer or TOPCON Data Collector,
which enables the computer to receive measured data from the GM or to send preset data of horizontal
angle, etc. to it.
The following data will be output at each mode.
•
The display and the output at the coarse mode are the same as the contents above.
•
Output at the tracking mode is displayed as distance data only.
The details necessary for the connection with the GM are obtained from the GM-50 series Interface
Manual which is optionally available. Please refer to the manual.
1.7
Bluetooth
communication (Only for
Bluetooth function
built-in
model)
By built-in
Bluetooth
, it can communicate with
Bluetooth
instruments by wireless, without connecting a
serial signal connector.
Mode
Output
Angle mode (V, HR or HL) (V in percent)
V, HR (or HL)
Horizontal distance mode (HR, HD, VD)
V, HR, HD, VD
Slope distance mode (V, HR, SD)
V, HR, SD, HD
Coordinate mode
N, E, Z, HR (or V, HR, SD, N, E, Z)