3-2
3 ANGLE MEASUREMENT
3.3 Measuring from the Required Horizontal Angle
3.3.1 Setting by Holding the Angle
Make sure the mode is angle measurement.
3.3.2 Setting a Horizontal Angle from the Keys
Make sure the mode is Angle measurement.
Operating procedure
Operation
Display
1
Set the required horizontal angle, using
Horizontal tangent screw
Display angle
2
Press the
{F2}
(HOLD) key.
{F2}
3
Collimate the target.
Collimate
4
Press the
{F3}
(YES) key to finish holding the
horizontal angle.*1)
The display turns back to normal angle
measurement mode.
{F3}
*1) To return to the previous mode, press the
{F4}
(NO) key.
Operating procedure
Operation
Display
1
Collimate the target.
Collimate
2
Press the
{F3}
(HSET) key.
{F3}
3
Input the required horizontal angle by
using keys. *1)
For example:70°40'20"
When completed, normal measuring from the
required Horizontal angle is possible.
70.4020
{F4}
*1) To enter Alphanumeric characters, see Section 2.4 “How to Enter Alphanumeric Characters”.
V :
90°10'20"
HR:
130°40'20"
0SET HOLD HSET
P1
↓
H ANGLE HOLD
HR:
130°40'20"
>SET ?
--- --- [YES][NO]
V :
90°10'20"
HR:
130°40'20"
0SET HOLD HSET P1
↓
V :
90°10'20"
HR:
170°30'20"
0SET HOLD HSET
P1
↓
H ANGLE SET
HR=
--- --- [CLR] [ENT]
V :
90°10'20"
HR:
70°40'20"
0SET HOLD HSET
P1
↓