17-1
17 SELECTING MODE
17
SELECTING MODE
17.1 Items of the Selecting Mode
The following modes are available.
Menu
Items
Selecting item
Display
1:
UNIT SET
TEMP. &
PRES.
°C/°F
hPa / mmHg /inHg
Select the unit of temperature for atmospheric
correction. Select the unit of air pressure for
atmospheric correction.
ANGLE
DEG (360°)/
GON (400 G)/
MIL (6400 M)
Choose degree, gon or mil unit for measuring
angle.
DISTANCE
m/ft/ft + in
Choose measuring unit for distance meter, feet or
feet and inch
FEET
US SURVEY/
INTERNATIONAL
Select the meter / feet conversion factor.
US SURVEY feet
1 m = 3.280833333333333 ft.
INTERNATIONAL feet
1 m = 3.280839895013123 ft.
2:
MODE SET
POWER ON
MODE
ANGLE MEAS./
DISTANCE MEAS.
Select to set the measurement mode for angle or
distance when the power is turned on.
FINE/CRS/
TRK
FINE/COARSE/
TRACK
Select Fine /Coarse / Tracking mode in distance
measurement mode, when the power is turned
on.
HD&VD/SD
HD&VD/SD
Specify which is displayed first, horizontal and
vertical distance or slope distance, when the
power is turned on.
V ANGLE
Z0/H0
ZENITH 0/
HORIZONTAL 0
Choose the vertical angle reading from zenith or
from level.
N-TIMES /
REPEAT
N-TIMES/REPEAT
Select the measurement mode for distance when
the power is turned on.
TIMES OF
MEAS.
0 to 99
Set N (number of times) for times of distance
measurement. When setting number of times as
1or 0, it is single measurement.
NEZ / ENZ
NEZ/ENZ
Select a coordinate displaying order either NEZ
or ENZ.
HA MEMORY
ON/OFF
Horizontal angle set can be retained after the
power is turned off.
ESC KEY
MODE
DATA COLLECT/
LAYOUT/REC/OFF
You can select a function of the
{ESC}
key.
DATA COLLECT/LAYOUT: It is possible to enter
data input mode (in DATA COLLECT) or Layout
Menu from normal measuring mode directly.
REC: While executing normal or offset
measuring, the measuring data can be output.
OFF: Returns to normal function.
COORD.
CHECK
ON/OFF
Select coordinate displaying ON or OFF when
setting a point.
FINE
READING
0.1 mm/1 mm
Select 1 mm or 0.1 mm for the minimum reading
unit in the distance mode (FINE mode).