Press the CONNECT button. When this is done, "Awaiting Network Response" may be seen briefly in Line
1 of the display, then the display will clear.
Proceed to 40d Network Feature Button Checkout (page 83).
NOTE
– On occasion, if the CONNECT button is pressed immediately after dialing the last digit of the
DN, an error tone may be heard. Press the CONNECT button again.
If after pressing the CONNECT button numerous times, an error beep continues to be heard, enter the
Maintenance Mode, select SETUP, select LOOPS, and verify that there are sufficient CAs with loop values
of either ORIG or N/R. There should be a minimum of two (2) CAs programmed as ORIG. As a safety
factor, it is recommended that an additional one or two of the balance of CAs are programmed as N/R.
If upon pressing the CONNECT button, the following display is shown continuously:
• Enter the Maintenance Mode, select SETUP, select KEYS, press the CONNECT button to view its
button number. The factory default is 60.
• Contact your telco representative to verify that network feature activator assigned to TRANSFER
(or CONFERENCE on Siemens EWSD) matches the button number viewed in this step.
• After reconciling network translations and the 40d program, repeat the procedures in this section.
NOTE
– This test procedure is only applicable when the 40d console is connected to a National
ISDN network.
40d Network Feature Button Checkout
At the appropriate point in the call process being tested, press the associated network feature button.
Please refer to the 40d120 Attendant’s Guide if necessary.
Upon successful initiation of a network controlled feature, the appropriate feedback can be viewed in the
display, via the LED above the button pressed, or both.
If upon pressing a feature button an error beep is heard or the network feature does not work properly,
enter the Maintenance Mode, select SETUP, select KEYS, then press the button in question. Verify that the
console button assignment matches the appropriate network feature activator configured on the line. Make
the appropriate programming changes and repeat the previous procedures in this section.
If the network feature still does not work, contact your telco representative to verify that:
• The network feature activator configured on the line matches the button assignment programmed
on the console.
• The network feature is properly configured or enabled on the line.
After reconciling network translations and the 40d program, repeat the procedures in the first three
paragraphs in this section.
13-102633 Rev. H
Page 83
Tone Commander 40d120 Installation Instructions
TRANS: Awaiting Network Response
XX:XX
Screen 22
DIAL Enter #
XX:XX
HOLD Internal
717 555-1492
Screen 21
Содержание 40d120
Страница 34: ...Page 34 13 102633 Rev H Tone Commander 40d120 Installation Instructions Figure 4 Typical Installation...
Страница 118: ...Page 118 13 102633 Rev H Tone Commander 40d120 Installation Instructions...
Страница 126: ...Page 126 13 102633 Rev H Tone Commander 40d120 Installation Instructions...
Страница 132: ...Page 132 13 102633 Rev H Tone Commander 40d120 Installation Instructions...
Страница 142: ...Page 142 13 102633 Rev H Tone Commander 40d120 Installation Instructions...