TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
REMEDY
No hydraulic pressure in system
1. Hydraulic relief valve setting incorrect
2. Hydraulic relief valve relieving below
set pressure
3. Hydraulic cylinder piston rings and
seals worn
4. Decompression valve stuck open
1. Reset to specifications
2. Repair or replace
3. Replace worn rings and seals
4. Repair or replace
Hydraulic pump making excessive noise 1. Closed or restricted liquid supply line
2. Leak in fluid intake line
3. Leak at pump shaft packing and/or
seals
4. Hydraulic fluid level low
5. Fluid viscosity too high (especially in
cold conditions)
6. Pump coupling loose or worn
1. Check supply valve and/or strainer or
filter
2. Repair
3. Repair
4. Add hydraulic fluid to proper level
5. Use hydraulic fluid with a lower vis-
cosity or install a low density immer-
sion heater suitable for hydraulic fluid
(contact Tomco for more information)
6. Tighten or replace
Excessive wear or breakage of pump
parts
1. Abrasive material in hydraulic fluid
2. Hydraulic fluid does not meet specifi
cations
3. Other
1. Replace or clean hydraulic fluid filter,
clean hydraulic reservoir and change
hydraulic fluid
2. Use hydraulic fluid with a viscosity of
150-300 SUS (ISO 32-68) @ 100 ºF
(37.7 ºC) such as Rando HD68 or
equal
3. See problem
Hydraulic pump making
Hydraulic fluid leaks from around pump
shaft or housing
1. Pump shaft packing and/or seals
worn
2. Head packing seals damaged
3. Excessive case pressure due to re-
stricted case drain flow to tank
1. Replace worn packing and seals
2. Replace damaged head packing
seals
3. Clean case drain line
Control Panel Message
“MOTOR OVERLOAD”
1. Excessive hydraulic pump pressure
2. Moisture on extrusion die or inside
compression cylinder
1. Check pump pressure control set-
tings
2. Remove extrusion die, clean and dry
die and inside of compression
cylinder thoroughly and reinstall,
being certain to torque according the
procedures on page 4.12
Control Panel Message
“LOW OIL LEVEL”
1. Possible leaks in hydraulic system
1. Repair leaks, add hydraulic fluid to
proper level
5.3
Содержание DE89RB- 1000
Страница 1: ...CARBON DIOXIDE DRY ICE PELLETIZER OPERATION MAINTENANCE MANUAL ...
Страница 2: ...ii ...
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 7: ...INTRODUCTION SECTION 1 0 1 ...
Страница 15: ...CARBON DIOXIDE SAFETY SECTION 2 0 2 ...
Страница 18: ......
Страница 19: ...INSTALLATION SECTION 3 0 3 ...
Страница 24: ......
Страница 25: ...OPERATION MAINTENANCE SECTION 4 0 4 ...
Страница 48: ......
Страница 49: ...TROUBLE SHOOTING SECTION 5 0 5 ...
Страница 54: ......
Страница 55: ...REPAIR ADJUSTMENTS SECTION 6 0 6 ...
Страница 66: ......
Страница 67: ...APPENDIX SECTION 7 0 7 ...
Страница 81: ...NOTES 7 14 APPENDIX ...
Страница 82: ...NOTES 7 15 APPENDIX ...
Страница 85: ......
Страница 86: ......
Страница 87: ......