OPERATION & MAINTENANCE
4.12
6. Completely dry the filter screen with CO
2
vapor or a dry air source.
7. Check all gaskets and replace any that are torn or cracked.
8. Reassemble in the reverse order.
Figure 4.1.1 - Models DE89RB-100-US, HP-200 & LB-450
Transition Box Assembly Exploded View
TRANSITION BOX
GASKET
FILTER SCREEN RETAINING PLATE
FILTER SCREEN
Figure 4.1.2 - Models DE89RB-500, DE89RB-1000, HP-500, HP-1000, DE89RB-1500
and High Capacity Transition Box Assembly Exploded View
TRANSITION BOX
GASKET (O-RING ON HIGH CAPACITY)
FILTER SCREEN RETAINING PLATE
FILTER SCREEN
GASKET (O-RING ON HIGH CAPAICTY)
SPACERS