3. CONNECTIONS
IP-3010AF Network PA I/O Interface
Power Connections
[When using the 24V DC power supply]
Connect the 24V DC power supply to the interface’s DC power input terminal (DC
INPUT).
NOTE:
Use a DC power supply with a rated
output current exceeding 1A.
The input voltage range of the DC power
input terminals is 21.6 ~ 26.4V DC.
Inputting a voltage outside this range could
lead to malfunctions or failures.
For wiring of the connector that connects to
the DC power input terminal, please refer to
Page 2-6 “Detachable Terminal Plug
Connections.”
If power is supplied to both the DC
power input terminal and the AC adapter
jack, the input with higher voltage will be used.
[When using the optional AD-246 adapter]
[Caution]
When using an AC adapter, use the optional AD-246 Adapter. Use of an AC adapter
other than the AD-246 could cause fire or other damage.
Connect the optional AD-246 Adapter to the interface’s AC adapter jack.
NOTE:
If power is supplied to both the AC
adapter jack and the DC power input
terminal, the input with higher voltage
will be used.
AD-246 AC Adapter
(optional)