– 129 –
Maintenance Settings
Synchronize the time among connected components and set log collection intervals
for the system.
Item
Description
Clock Synchronization
Time
Set the time to synchronize clocks at among the System Manager PC,
IP-3010AF, IP-3001AF and IP-300RM.
Contact Input
Set the component’s contact input to be connected to the master clock’s
contact output for clock synchronization.
Receiving Time
Set the time to correct the System Manager PC’s clock. If the contact set in
the ‘Contact Input’ settings is closed within ±15 seconds of the correction time,
the clock will be corrected.
Setting Method
1. Set each setting item.
Receiving times can be added by clicking the ‘Add’ button.
2. When acquiring an equipment log, click the ‘Acquire Equipment Log’ button.
When clicked, the equipment logs for the system’s IP-3010AF, IP-3001AF and
IP-300RM are instantly acquired.
Equipment log storage location and file format
— Acquired equipment logs are stored in the following folder of the System
Manager PC in order of date.
Folder
C:¥ProgramData¥TOA¥IP-3000SM¥EquipmentLog
Filename
Equipment name yyyymmdd.log
— Stored equipment logs can be opened using Memopad or another text editor.
Operation Buttons
Cancel:
Reverts to the Home screen without saving any setting.
Next:
Advances to the ‘Firmware Settings’ screen.
Return:
Reverts to the ‘User Settings’ screen.
Содержание IP-3000SM
Страница 7: ... 7 CHAPTER 1 SYSTEM SUMMARY ...
Страница 17: ... 17 CHAPTER 2 INSTALLATION AND CONNECTIONS ...
Страница 25: ... 25 IP 3001AF Interface Audio Input Output Signal Terminal Wiring Method Detachable Terminal Plug Connections ...
Страница 26: ... 26 IP 300XI Module Settings Note AX 0120 0240 FS 9250DA and DA 520H are products sold only for regions ...
Страница 33: ... 33 CHAPTER 3 FUNCTIONS AND OPERATION ...
Страница 80: ... 80 CHAPTER 4 SYSTEM SETTINGS ...