DIGITAL WEIGHING INDICATOR TI-5700
- 39 -
Normal batching 2 (F21-5)
◊
Relay output signal is as follows.
1. Press TARE key so that the display shows 0kg.
2. Preliminary: It is ON when the net weight is greater than the weight
(Final
– Preliminary).
3. Final: It is ON when the net weight is greater than the weight (Final
– Free fall).
4. Zero band: It is ON when gross weight is lower than zero band value.
◊
Status and display lamp
Display lamp
HI
OK
LO
Status
Final
Preliminary
Zero band