DIGITAL WEIGHING INDICATOR TI-5700
- 52 -
13. Analog Output (OP-04)
◆
TI-5700 has two analog output modes (4~20mA / 0~10V).
But two types of analog output can
‟t be used simultaneously.
◆
The analog output option is for sending the weight data to an analog input unit.
◆
The output data is updated in synchronization with the display update.
13.1. Specifications
◊ Output level: 4~20mA, 0~10V
◊ Resolution: 16bits
◊ Full scale error: ±0.001%FSR
◊ Temperature coefficient: ±1ppm FSR/°C
13.2. Pin connection
◊
Adaptable connector: D-sub 9 pin connector (Female)
Pin
Name
Description
1
VS+
0~10V +Sense
2
VOUT
0~10V output
3
VS-
0~10V -Sense
5
GND
GND
6
IOUT
4~20mA output
◊ Voltage output error due to the wire length is automatically compensated.
If you do not use the auto compensation function, It is possible to connect a 2
wire cable provided that pins VS+ / VOUT and pins VS-/GND are shorted.
13.3. Setting
Output can be scaled from zero to full capacity by F54 and F55.