![TMT TI-5700 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/tmt/ti-5700/ti-5700_operation-manual_1121995025.webp)
DIGITAL WEIGHING INDICATOR TI-5700
- 25 -
◊
F25: Start delay time of finish signal for F21: 4,7 (00~99)
Value
Description
00
0.0 sec.
It is used when delay time of output is set after Final.
(Works only when the weight is stable)
40
4.0 sec.
99
9.9 sec.
◊
F26: Item code number (0~7)
Value
Description
0
Item code number 0
3
Item code number 3
7
Item code number 7
◊
F27: High limit weight for F21: 1~9
◊
F28: Low limit weight for F21: 1~9
◊
F29: Zero band for F21: 1~9
◊
F30: Final weight for F21: 4~9
◊
F31: Free fall weight for F21: 4~9
◊
F32: Preliminary or Full weight for F21: 5, 6, 8, 9
The decimal point is not displayed when inputting value of F27 to F32.
If input value is 200 in one decimal point, the actual value is 20.0.