DIGITAL WEIGHING INDICATOR TI-5700
- 43 -
Loss in weight batching (F21-9)
Relay OK output can be changed to Over/Under/Full by setting F23.
◊
Relay output signal is as follows.
1. Full: It is ON when the gross weight is greater than Full weight and OK lamp
turns on. It is OFF when the gross weight is lower than Full weight.
2. Press TARE key so that the display shows 0kg.
3. Start input: Final output are ON when start input is ON.
4. Final: It is OFF when the net weight is greater than the weight (Final
– Free fall).
5. Over: It is ON when the net weight is greater than the weight (Final + High limit)
after Final output is OFF and HI lamp turns on.
6. Under: It is OFF when the net weight is greater than the weight (Final
– Low limit)
after Final output is OFF and LO lamp turns on.
7. Zero band: It is ON when gross weight is lower than zero band value.
8. Stop input: The weighing completion condition is set by F22: 1x.
F22-10 : Either the STOP key is pressed or the Batch stop input is on.
F22-11 : Stop when weight is stable after reaching Final.
◊
Status and display lamp
Display lamp
HI
OK
LO
Status
Over
Final
Under