DIGITAL WEIGHING INDICATOR TI-5700
- 19 -
◊
F02: Zero tracking (0~10)
Value
Description
00
OFF
The zero tracking function will automatically bring the
display back to zero when there are small deviations.
For example:
F02-02
setting.
As shown in the figure below, display will automatically
zero at less than 1digit per second.
01
0.5d/1sec.
02
1.0d/1sec.
03
1.5d/1sec.
04
2.0d/1sec.
05
2.5d/1sec.
06
0.5d/2sec.
07
1.0d/2sec.
08
1.5d/2sec.
09
2.0d/2sec.
10
2.5d/2sec.
◊ F03: Motion detection (0~10)
Value
Description
00
OFF
Per each A/D conversion, the current weight is
compared to previous weight by this parameter.
If any of the set parameters are exceeded, stable
display goes off.
The ZERO key and TARE key are active in the stable
state. If these keys need to be active in the unstable
state, set to
F03-00
.
01
0.5d/0.5sec.
02
1.0d/0.5sec.
03
2.0d/0.5sec.
04
3.0d/0.5sec.
05
4.0d/0.5sec.
06
0.5d/1sec.
07
1.0d/1sec.
08
2.0d/1sec.
09
3.0d/1sec.
10
4.0d/1sec.
◊
F04: Weight backup (0,1)
Value
Description
0
OFF
If this function is active, In case occurring sudden power
failure, it can be memory the moment value.
1
ON