172-65702M-04 (SQ-C01) 10 Dec 2020
34
6) Remove the heat exchanger unit to be replaced and install the new unit by
following the above procedures in reverse. Gaskets must be replaced if
disassembled.
(3) Pre-mixing Valve
Components required: (1) Pre-mixing Valve
Replacement Kit × 1
1) Loosen and remove the cover of the
pre-mixing valve.
2) Take out the replacement parts.
(Do not forget to take out the part to be
replaced.)
3) Insert the replacement kit for the
pre-mixing valve. Tighten the cover.
(Tightening torque of the cover: 40 N
m)
(4) Mixing Unit
Components required: (1) Mixing Valve Unit × 1
1) Loosen the G threaded connector on the
flexible tube connected to the mixing valve
unit. (Two locations)
Loosen the union that is connecting the
mixing unit and the pre-mixing unit and
remove the screw.
2) Loosen nuts of the U bolt in two locations
fixing the mixing valve to the base and
remove the U bolt.