172-65702M-04  (SQ-C01)    10  Dec  2020

 

37

 

Troubleshooting 

 

 

Be sure to use only the recommended components when repairing the 

unit and its components, and NEVER attempt to modify the unit in any 

way. Failure to observe these precautions may result in damage to the 

unit or burns or other injury due to malfunction or the discharge of fluids.

 

CAUTION 

 

 

Do not apply excessive force to the unit, pipings, and peripheral piping. 

Failure to do so may result in injury or deformation of the device.

 

CAUTION 

 

 

When disassembling or removing the unit, wait until the internal pressure 

equals atmospheric pressure and the surface of the unit has cooled to 

room temperature. Disassembling or removing the unit when it is hot or 

under pressure may lead to discharge of fluids, causing burns, other 

injuries or damage.

 

CAUTION 

 

 

When all the piping work is completed based on the system flow 

diagram, inspect once again that all the piping connections and 

internal G threaded connectors are properly tightened, gaskets have 

been installed and that no parts or connections are loose. Failure to do 

so may result in burns or other injury from discharge of fluids.

 

CAUTION 

 

 

Make sure to wear protective gear such as a helmet, safety glasses, 

long-sleeve shirt, heat-resistant gloves, protective footwear, etc.  

Failure to do so may result in burns or injuries.

 

CAUTION 

When the unit fails to operate properly, use the following table to locate the cause 
and remedy. If it is not possible to resolve the problem even after performing the 
remedy below, contact TLV. 

 

* Refer to individual instruction manuals for further details on components mentioned in this 

manual. 

 

Problem 

Cause 

Diagnosis 

Remedy 

No hot water is 
discharged 

Valves on piping are 
closed 

Check valves 

Operate the valve in 
accordance with the 
operating procedures. 

The strainer on the 
cold inlet piping is 
clogged 

Check the strainer on 
the cold inlet piping 

Clean the strainer on 
the cold inlet piping 

The adjustment valve 
at the hot water side in 
the mixing valve is 
clogged 

Confirm that the water 
temperature at the 
outlet of the heat 
exchanger is high. 

Replace with a new 
mixing valve 

Temperature 
does not rise 
as required 
 
Water 
temperature is 
unstable 
 

Supply steam pressure 
is decreased or stem 
supply quantity is 
insufficient 

Check the settings of 
the pressure reducing 
valve (at the water 
supply side and in the 
unit) 

Set the maximum 
steam pressure that 
can be supplied below 
0.7 MPaG. 
Set the pressure of the 
pressure reducing 
valve in the unit 
designated pressure. 

Supply steam pressure 
is unstable 

Check the steam 
pressure 
Check for pipe 
leakage 

Make sure that steam 
with a pressure of 0.6 
MPaG or less can be 
obtained stably before 
the unit. 

Continued on the next page 

Содержание SteamAqua SQ-C01

Страница 1: ...172 65702M 04 SQ C01 10 December 2020 Steam Fired Instantaneous Water Heater SQ C01 Copyright 2020 by TLV CO LTD All rights reserved...

Страница 2: ...ir work Please keep it in a safe place for future reference The copyright of this manual belongs to TLV CO LTD Unauthorized reproduction of the contents of this manual in part or in whole is strictly...

Страница 3: ...d Function 9 Options 11 Considerations for Installation Personnel 12 Precautions before Unit and Piping Installation 14 Piping Work 16 Commissioning 21 Operation 24 Prevention of Damage due to Freezin...

Страница 4: ...N The three types of cautionary items above are very important for safety be sure to observe all of them as they relate to installation use maintenance and repair Furthermore TLV accepts no responsibi...

Страница 5: ...esult in back strain or other injury if the object should fall To use the unit safely and properly read this instruction manual carefully to carry out the specified work Installation moving and incide...

Страница 6: ...lectrical power water and air Failure to prevent the access of unauthorized personnel may result in burns electric shock injury or falls Precautions for Operation CAUTION Hot water may flow out when w...

Страница 7: ...nit are hot Precautions when the Unit is Shut Down for a Long Period of Time CAUTION When the unit is shut down for a long period of time or there is a possibility of freezing make sure to completely...

Страница 8: ...all Butterfly Valve TLV BB1N size 15 mm Rc 3 Note Gaskets bolts and nuts required to connect the unit to piping are not included Make sure to read the documentation packed with the unit as well as thi...

Страница 9: ...n or other injury if the object should fall CAUTION Follow the procedures below for moving the unit Moving procedures 1 Remove all items from the packaging except the unit 2 Remove the unit from the b...

Страница 10: ...etails Chart Name Connection A Steam Inlet 15 mm JIS 5KFF or 15 ASME Class 150 RF B Condensate Outlet 15 mm JIS 5KFF or 15 ASME Class 150 RF C Cold Water Inlet 15 mm JIS 10KFF or 15 ASME Class 150 RF...

Страница 11: ...mally high temperature water from being discharged Heat insulating joint Mixing Unit Mixing Valve Produces hot water of the required temperature by mixing hot water and cold water that have passed thr...

Страница 12: ...from the supplied steam to prevent it from flowing into the unit TLV Y3 strainer Rc Ball Butterfly Valve for steam inlet cold water inlet and hot water outlet Install valves on each piping connection...

Страница 13: ...rk based on the Before commissioning in the Installation Check List on the following page b Make sure to observe the safety precautions when performing commissioning c After completing commissioning c...

Страница 14: ...tightened Have piping supports been firmly installed Are the supply conditions for steam and water appropriate Has piping in the unit been additionally tightened after installation After commissioning...

Страница 15: ...r 3 When installing the unit in a high place make sure to install the unit at a location where maintenance work etc can be carried out and where handrails etc are installed to prevent falling If work...

Страница 16: ...arge condensate before operation Flushing is performed to remove the residual sealing material metal chips sand or scale in the piping Therefore it is necessary to vigorously flush the piping from as...

Страница 17: ...ded pipes to the unit Over tightening may cause breakage leading to fluid discharge which may cause burns or other injury CAUTION The unit consists of steam using equipment and piping Proper insulatio...

Страница 18: ...e instructions provided by the organization that designed and installed the system 2 Precautions for installing piping Do not apply excessive force to the the unit pipings and peripheral piping Failur...

Страница 19: ...valve on the secondary side of the steam trap to prevent backflow g Make sure to insulate the steam piping as it becomes very hot h When using a pressure reducing valve to supply steam to the unit mak...

Страница 20: ...When recovering the condensate install a check valve on the secondary side of the steam trap to prevent backflow when the unit is shut down The back pressure of the condensate recovery piping should b...

Страница 21: ...ven when the unit is not in operation the water safety valve may operate and hot water may flow out to prevent the internal pressure from rising Failure to follow precautions may result in burns or ot...

Страница 22: ...main steam supply valve and shut down the unit promptly If the tube inside the heat exchanger of this unit is damaged due to an earthquake a large amount of steam will enter the hot water piping whic...

Страница 23: ...tightened c Checking opening closing of valves Check to make sure that valves installed on the steam inlet piping cold water inlet piping and hot water outlet piping are closed Furthermore close the...

Страница 24: ...y water to the unit and vent the air 4 Open the valve C on the condensate outlet piping so the condensate is discharged 5 Close the valve D on the steam inlet piping slowly and supply steam 6 When the...

Страница 25: ...se the main steam supply valve and shut down the unit promptly If the tube inside the heat exchanger of this unit is damaged due to an earthquake a large amount of steam will enter the hot water pipin...

Страница 26: ...the unit is not adjusted open the pressure reducing valve by slowly turning the handle and adjust to the designated pressure 7 Check to make sure that the steam pressure is stable and adjust the water...

Страница 27: ...t the intended location for use 1 Close the steam inlet valve D slowly 2 When the valve B on the hot water outlet piping is closed open the valve slowly and supply water for a while 3 After supplying...

Страница 28: ...damaged due to freezing repair will be billed even during the warranty period Water in the water supply system cannot be discharged with the unit To prevent freezing of the water supply system contact...

Страница 29: ...discharge of fluids CAUTION There are two types of inspection for maintenance of the unit operational checks and cleaning The operational check includes inspection items based on visual and hearing so...

Страница 30: ...172 65702M 04 SQ C01 10 Dec 2020 29 If there are any abnormalities in the operational check items inspection and repair should be requested immediately...

Страница 31: ...the strainer Make sure to close the supply water tap before cleaning the strainer 1 Close the supply water tap 2 Loosen the screen holder with tools such as an adjustable spanner or hex spanner 3 Rem...

Страница 32: ...rotective gear such as a helmet safety glasses long sleeve shirt heat resistant gloves protective footwear etc Failure to do so may result in burns or injuries CAUTION Stop steam and water supply and...

Страница 33: ...oval of the pipe thread taper thread may be difficult as a sealant is used to prevent water leakage 1 When replacing only internal parts of the pressure reducing valve refer to the instruction manual...

Страница 34: ...er connected to the mixing valve located in front of the heat exchanger There are two locations where G threaded connectors are used 2 Loosen the union connected to the steam supply unit 3 Loosen the...

Страница 35: ...replacement parts Do not forget to take out the part to be replaced 3 Insert the replacement kit for the pre mixing valve Tighten the cover Tightening torque of the cover 40 N m 4 Mixing Unit Compone...

Страница 36: ...lexible tube Remove hex bolts M4 with washer that are holding the frame and the piping Be careful not to drop the nuts 3 Remove the hot water outlet unit holding it with two hands Remove the hot water...

Страница 37: ...pre mixing unit and the heat isolation fitting 1 Loosen the two G threaded connectors at the inlet of the pre mixing unit Be careful as residual condensate may flow out 2 Loosen the G threaded connect...

Страница 38: ...otective footwear etc Failure to do so may result in burns or injuries CAUTION When the unit fails to operate properly use the following table to locate the cause and remedy If it is not possible to r...

Страница 39: ...temperature with another thermometer Replace with a new thermometer if it is judged to be defective Large fluctuations of the amount of hot water used Check hot water usage When a large amount of hot...

Страница 40: ...emperature Adjustment Method Dial type Temperature Adjustment Range 30 to 50 C 40 to 65 C Supply Pressure Steam 0 2 to 0 7 MPaG Cold water fluid pressure 0 1 to 0 4 MPaG Temperature 5 to 28 C Maximum...

Страница 41: ...unit indoors to prevent it from getting wet by rainwater dew etc 2 Store the unit indoors with humidity less than 80 3 If the label or plastic sheet used for sealing or packaging of the unit is damag...

Страница 42: ...or defaced nor does it apply in the following cases 1 Malfunctions due to improper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt...

Страница 43: ...ia 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Road Shanghai China 20...

Отзывы: