172-65720MA-00 (FJ32-X+BD2) 22 Dec 2021
6
Specifications
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or malfunctions
that may lead to serious accidents. Local regulations may restrict the use of this
product to below the conditions quoted.
DO NOT use this product in excess of the maximum operating pressure
differential.
Such use could make discharge impossible (blocked).
Use only under conditions in which no freeze-up will occur.
Freezing may damage the product, leading to fluid discharge, which may cause burns
or other injury.
Refer to the product nameplate for detailed specifications.
The specifications displayed on each nameplate apply only to the unit on which it is
mounted. When a trap unit is installed on a connector unit and the PMA/TMA and/or
PMO/TMO values displayed on the two nameplates differ, the specifications for the
assembled products are restricted to the lower values.
Trap Unit
Connector Unit (mounted only on F46)
A
Model
B
Nominal Diameter
C
Maximum Allowable Pressure (PMA)*
D
Maximum Allowable Temperature (TMA)*
E
Maximum Differential Pressure (PMX)
F
Maximum Operating Temperature (TMO)
G
Production Lot No.
H
Valve No.**
*Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS,
NOT
OPERATING CONDITIONS.
**Valve No. is displayed for products with options. This item is omitted from the nameplate
when there are no options.
Compatibility
The FJ32-X QuickTrap employs connector unit F46 and is not compatible with
QuickTrap models using connector unit F46J. The J32-X trap unit is compatible with
trap stations (V1/V2/V1P/V2P Series) and Quick Station QS10, and can also be
installed on connector unit F32.
The unit name is embossed on the connector body.
CAUTION