![Timewave DSP-D300 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/timewave/dsp-d300/dsp-d300_manual_1117522086.webp)
WARNING!
Take a look at the image version number (the
xxx
in
imagev
xxx
_). If the image file has an odd number, then it
for a Version 2 Ethernet module, otherwise it is Version 1
firmware.
Example: imagev220_20070503.bin is Version 1.
Example: imagev225_20070503.bin is Version 2.
To determine which version of the Ethernet module is in the
DSP-D300, either check the serial number or check the
version displayed in the shell. If it gives a version for SSL,
then it is the Version 2. Contact Timewave for information
if you are not sure.
Serial Numbers for the Version 1 Ethernet Module: (v220
firmware): 25000, 25001, 25003-25039, 25041
All other D300 Boxes will have the Version 2 Ethernet
Module.
5.
From the “$” prompt, type the following:
$ loadimage image.bin 192.168.1.100
Where the IP address is the IP address of the TFTP server.
6.
Wait for the download.
7.
Type the following to make sure the image is good:
$ verifyimage image.bin 192.168.1.100
Where the IP address is the IP address of the TFTP server. This will redownload
and compare the files.
8.
To update the firmware, type “updateimage”. This may take 10 minutes.
DO
NOT disconnect the power during this operation!
Doing so will require that the
unit be sent back to Timewave for repairs. Wait for the prompt to reappear. You
may hit
Enter
to see if the prompt has returned if you believe the update has
finished.
$ updateimage
9.
Reboot the Ethernet module by typing “reboot” or cycling the power.
$ reboot
86
Содержание DSP-D300
Страница 2: ......
Страница 6: ...Table of Figures 106 Glossary 108 Index 110 6...
Страница 33: ......
Страница 55: ......
Страница 59: ......
Страница 71: ......
Страница 77: ...4 Flip the box over Remove the two circuit board screws These may have washers Board Screws 77...
Страница 87: ......
Страница 89: ......
Страница 97: ......
Страница 103: ......
Страница 105: ......
Страница 107: ......