1
2
1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire
is switched off and the circuit supply fuses are removed or the circuit breaker
turned off.
• It is recommended that a qualified electrician is consulted or used
for the installation of this luminaire and install in accordance with
the current IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted
does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This luminaire is of class II construction and must not be earthed
• 10W LED Non-replaceable lamp
• Energy efficiency:
Class A+
• Energy Usage:
10kWh/1000H
• Lumen Output:
800lm
• Colour Temperature:
4000K
• Transmission Power:
<0.2mW
• Working Frequency:
5.8GHz
• Standby Power Consumption: 0.9W approx.
• Detection Angle:
360°
• Adjustable Detection Range: 1 to 8m (radius)
• Adjustable Time Delay:
10 seconds to 30 minutes
• Dusk Level Adjustment:
10 to 2000 Lux
• IP44 Rated suitable for restricted external applications
• Operating Temperature:
-15°C to +45°C