7. Setting Up
• Take note of the 3 adjusters located beneath the diffuser/lens;
• By default the 3 adjusters will be set as follows in order for you to complete
a full walk test (from powering the unit ON for the first time);
TIME
fully anticlockwise to its minimum (approx. 10 seconds time delay).
LUX
fully clockwise to its minimum (full day and night time operation).
SENS
fully clockwise to its maximum (maximum detection range).
Walk Test Procedure
• Turn the power to the unit ON. The lamp will immediately illuminate for
approximately 2 seconds and then will extinguish. This indicates the unit
is wired correctly.
• The unit will now operate during daytime as well as at night, illuminating
the lamp for approx. 10 seconds each time. This allows testing to be carried
out to establish whether the sensor is covering the required area.
• Walk across the location the luminaire is fitted, to establish the detection area.
• With sensitivity set to the maximum, the sensor will detect you within
an approximately 8 metre radius from the centre of the luminaire location
with a 2.5 metre ceiling mounting height.
• As you cross the detection “zone” the lamp will illuminate. Now stand still until
the lamp extinguishes (this should take approx. 10 seconds).
• Start moving again after 4 seconds. As you cross the detection zone the lamp
will illuminate.
• Repeat the above, walking at various distances and angles to the unit to confirm
the detection pattern.